MODEL | CY-25-5 | CY-25-12 | CY-25-24 |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
RATED CURRENT | 5A | 2A | 1A |
CURRENT RANGE | 0-5A | 0-2A | 0-1A |
RATED POWER | 25W | 25W | 25W |
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 100mVp-p | 100mVp-p |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 21.6 ~ 26.4V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ± 1.0% |
LINE REGULATION | ±0.5% | ± 0.5% | ± 0.5% |
LOAD REGULATION | ±1.0% | ± 0.5% | ± 0.5% |
SETUP, RISE TIME | 200ms 100ms |
HOLD UP TIME (Typ.) | 30ms |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY(Typ.) | 65% | 68% | 72% |
AC CURRENT (Typ.) | 0.6A/115VAC 0.35A/230VAC |
INRUSH CURRENT (Typ.) | COLD START 13A/115VAC 25A/230VAC |
LEAKAGE CURRENT | <0.75mA/240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
Protection type :Hiccup mode, recovers automatically after fault condition is removed. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60°C (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85°C, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL1012, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5, EN55024, light industry level, criteria A |
OTHERS | MTBF | 522.1K hrs min. MIL-HDBK-217F (25) °C |
DIMENSION | 95*58*28 (L*W*H) |
PACKING | 0.076Kg; 45pcs/15Kg/0.9CUFT |
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |