Item specifics
-
Brand Name
samwhadsp
-
Certification
CE
-
Origin
CN(Origin)
-
Theory
Thermal Relay
-
is_customized
Yes
-
Contact Load
Low Power
-
Voltage
380V
-
Model Number
SOPR-SS3-440
-
Protect Feature
Sealed
-
Power Source
AC
-
Usage
Protective
-
Operating Voltage(Un)
380VAC
-
Current Range(A)
0.5-6A / 3-30A / 5-60A / 10-120A
-
Main Circuit Wiring
Through Core
-
Relay output
1c
-
Protected object
motor
-
Model
EOCR/SOPR/DPR/EOPR
Features ■ Super Small ■ Over-Current Circuit Breaker Lock Protection ■ Separate Set-up for each Operation Delay / Operation Delay Time ■ Wide Range of Set-up ■ Wide Operating Voltage Range ■ Operation Indicator and Identification of Actual Current(LED) ■ Manual / Electric Reset ■ Ambient Insensitive ■ Low Energy Consumption ■(No Volt Release/Fail-safe Operation)→N Type ※Single-phase, three-phase available (No Volt Release/Fail-safe Operation)→N Used for - Low Voltage Induced Electromotor (600V Level) Protective Relay - Break-Down Watch Current Relay - Alternative Replacement for the Existing Relay Protetcion Protective Item Operating (Trip) Time
Over-Current = O-TIME
Phase Loss = O-TIME
Locked Rotor = D-TIME+O-TIME LED Ammeter Function: After the motor runs smoothly, turn the overcurrent setting knob slowly counter clockwise to the red indicator light, which is 100% of the actual running current. And then turn the knob clockwise to just turn off the red light at this point for the actual running current value of about 103%.
Run / Operation Indicator: Relay Trip: Red LED Power / normal operating status: Green LED Manual / Electric Reset With test button held down,the red LED is on and the product will trip after O-TIME.
The relay will be de-energized when RESET button is pushed or the control power is disconnected. Set After the installation is complete the settings as follows.
Set knob: D-TIME(Delay Time) Set two to three seconds longer than the motor starting time.
Set knob: O-TIME(Over-current run time) Set less than the motor's endurance time with over-current.
Set knob: Load(Rated Current) Set over 110% of the motor's rated current of under 120% of its operating current. TEST Instruction With test button ehld down,the red LED is on and the product will trip after O-TIME.
The relay will be de-energized when RESET button is pushed or the control power is disconnected. LED Indication Item PWR(Green)LED Trip(Red)LED Power ○ ×
Normal Running ○ ×
Trip × ○ Specifications Current Range............ : Type05) 1-6.5A
Type30) 5-30A
Type60) 5-60A Type120) 10-120a
Type600) Use an external CT(secondary 5A)over 60A with 05 type.
Operating Voltage(Un).: Tpye110) 110VAC Tpye220) 90-260VAC Tpye380) 180-460VAC
Operating Frequency....: 50/60Hz
Operating Power...........: <2W
Operating Temperature: -20℃·····+55℃
Waiting(t)......................: D-Time 0.2-60s O-Time 0.2-12s
Asymmetry Set.............: %±10
Contact.........................: 5A 250VAC Resistive Load
Connection Diagrams..: 35mm Din Rail(D) or Pane(P) Dimensions  Connection Diagram    |