Item specifics
-
Brand Name
samwhadsp
-
Certification
NONE
-
Origin
CN(Origin)
-
Theory
Voltage Relay
-
is_customized
Yes
-
Contact Load
Low Power
-
Voltage
220V
-
Model Number
GKM-11
-
Protect Feature
Sealed
-
Power Source
AC
-
Usage
Protective
-
Protection Item 1
Overvoltage
-
Protection Item 2
undervoltage
General Voltage control relays are designed to protect devices with sensitive operating voltage values from failures that may be caused by mains voltage. Usage and Working Principle Make the connections of the device in accordance with connection scheme. Set the required settings of the device according to the operating voltage values of te load. When the device is energized, if the voltage values are normal according to the set values, the relay gets activated and the relay LED(≠) is turned on. When the voltage values go out of the set values, the related fault LED is on, it waits until the delay time (DT), after the time has elapsed, the relay gets de-activated and the relay LED goes out. When the voltages return to their normal values, the device waits until the reset time (RT), after the time has elapsed the relay gets activated and the relay LED is turned on. Disable to Protection The High Voltage Protection function is deactivated when the HV control knob is set to Off.
The Low Voltage Protection function is deactivated when the LV control knob is set to Off.
The Off stage is limited to 140V. If the voltage falls below 140V while in this stage, the relay is deactivated and the LV Led is flashes. Relay Activated/De-activated Status Relay is Activated: 2 (COM) and 3 (NC) short circuit, 1 (NC) and 2 (COM open circuit. Relay is De-activated: 2 (COM) and 1 (NC) short circuit, 3 (NC) and 2 (COM) open circuit. Required Settings and Error Notifications HV Control Knob: High Voltage Set Value, when the voltage rises above this value, HV LED is on.
LV Control Knob: Low Voltage Set Value, when the voltage drops below this value, LV LED is on.
OT Control Knob: Delay Time, is the time to wait before entering the ailure.
RT Control Knob: Reset Time, is the time to wait for the relay to pull when the voltages return to norma.  Protection Functions High Voltage Protection - To enter the error state: If the voltage, goes above the high voltage set value, the HV LED is on, the device waits until the set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.
High Voltage Protection - Exiting the error state: When voltage, lower than 5 volts of the set high voltage set value, the device waits for the reset timé (RT). After the time passes, the HV LED is off the relay gets activated and the relay LED is on.
Low Voltage Protection - To enter the error state: If the voltage, goes below the low voltage set value, the LV LED is on, the device waits until the set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.
Low Voltage Protection - Exiting the error state: When voltage is higher than 5 volts of the set high voltage set value, the device waits for the reset time (RT). After the time passes, the LV LED is off the relay gets activated and the relay LED is on. Maintenance Switch off the device and release from connections. Clean the trunk of device with a swab. Don’t use any conductor or chemical might damage the device. Make sure device works after cleaning Warnings Please use the device according to the manual. Don’t use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device. Specifications Operating Voltage(Un)....: 220V AC Operating Frequency.......: 50/60 Hz. Operating Power...............: <6VA Operating Temperature..: -20°C.....+55°C High Voltage Set(U>)...........: 230V - 300V+OFF Low Voltage Set(U<)............: 150V - 210V+OFF Delay Time.......................: 0,5sec - 20sec. Relay Time.......................: 0,5sec - 20sec. Display.....................: 3x LEDs Connection Type.....: Terminal connection Contact.................:5A/250V AC (Resistive Load) Cable Diameter.................: 2,5mm² Weight................................: Max. 100gr. Mounting...........................: Vertical assembled in the panel or assembled on the din rail Operating Altitude..........: <2000meter Dimensions  Connection diagram    |