Item specifics
-
Brand Name
samwhadsp
-
Certification
CE
-
Origin
CN(Origin)
-
Theory
Voltage Relay
-
is_customized
Yes
-
Contact Load
Low Power
-
Voltage
380V
-
Model Number
DGK-04F
-
Protect Feature
Sealed
-
Power Source
AC
-
Usage
Protective
-
Protection Item 1
Overvoltage
-
Protection Item 2
undervoltage
-
Protection Item 3
loss phase
-
Protection Item 4
phase sequence
General DGK-04F voltage control relays are designed to block three-phase loads malfunctions arising from network. Usage and Working Principle Make the connections of the device in accordance with connection scheme.
To Adjust High Voltage Set: Value checking the value of display on the left, adjust the desirable value of (u>) button . Once you move the button , set value will be displayed. To Adjust Low Voltage Set: Value checking the value of display on the left, adjust the desirable value of (u<) button.
With the help of the button ,the adjustment is value of display on the left display. 4 seconds later, displayers show voltage values.
Once the device is energized, firstly the pre-adjusted set values are displayed and 2 seconds later voltage values appear. When R, S and T phases are between the adjusted voltage values, relay (Out) LED is on and contact (2-3) closed. If any between phase-phase is over high voltage set value, it holds for 3 seconds(fixed) and then relay (Out) LED is off, high voltage error (U>)LED is on and contact (2-3) opened. Whichever phase-phase voltage value is high, its display blinks, contact (2-3) opened. When voltage values declines 5V below set value, it holds for adjusted (t) knob time and then relay (Out) LED is on, high voltage error(U>) LED is off and contact (2-3) closed.
If any phase-phase declines below low voltage set value, it holds for adjusted (t) time and then relay(Out) LED is off, low voltage error LED(U<) is on and contact (2-3) opened. Whichever phase-phase voltage value is low, its display blinks, contact (2-3) opened. When voltage values inclines 5V above set value, it holds for adjusted (t) knob time and then relay (Out) LED is on, low voltage error LED(U<) is off and contact (2-3) closed.
Phase protection is available on DGK-04F/DGK-04PF. When phase sequence is reversed or phase loss, contact (2-3) opened and phase sequence error (X1) LED is on. Maintenance Switch off the device and release from connections. Clean the trunk of device with a swab. Don’t use any conductor or chemical might damage the device. Make sure device works after cleaning Warnings Please use the device according to the manual. Don’t use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device. Specifications Operating Voltage(Un)....: 3 x 380V AC Operating Frequency.......: 50/60 Hz. Operating Power...............: <6VA Operating Temperature..: -20°C.....+55°C High Voltage (U>)...........: 400V - 460V Low Voltage (U<)............: 230V - 360V Waiting (t).......................: 0,1sec - 10sec. Display..................: 3x 3digit 9mm display and leds Measurement Precision...: ±%1 Connection Type..............: Terminal connection Contact....................:5A/250V AC (Resistive Load) Cable Diameter.................: 2,5mm² Weight................................: Max. 220gr. Panel Hole Sizes................: 91x91mm Mounting...........................: Vertical assembled in the panel or assembled on the din rail Operating Altitude..........: <2000meter Dimensions  Connection diagram    |