Item specifics
Product Description
Baby description:
Note: For a meter with a range of 50A or 100A, no matter whether the measured current is less than 10A, a shunt must be connected to measure the current! Otherwise, the meter head will be burnt. Voltage display is normal, current display 0.00 or 0.0 Make sure that the thick black wire is connected to the negative terminal of the battery and the thick red wire is connected to the negative terminal of the load. (Note that the wiring of discharging and charging is not the same, see the concept of load and power supply after.). (The meter head uses the original imported chip, which has undergone very strict testing and calibration before leaving the factory. It is guaranteed. There is no quality problem before leaving the factory. 99.99% of the current display is 0 because the wiring is incorrect. Please check the wiring patiently and carefully) Inaccurate current display If it is directly powered or the independent power supply and the equipment power supply share the same ground, just disconnect the thin black wire to be accurate. No display when connected to power All the rectified AC power must be filtered by an electrolytic capacitor above 1000uF before it can supply power to the meter. Judge whether the header is good or not (the following are two cases of normal header) Without the shunt, connect the thin red wire and thin black wire to the power supply. The current of the meter with a range of 50A displays 50.0~59.9, and the meter with a range of 100A displays 100~109; Connect the shunt, connect the thin red wire and thin black wire to the power supply, the current of the meter with a range of 50A displays 0.00, and the meter with a range of 100A displays 0.0; Other matters needing attention The measured current can only be connected to the negative pole of the power supply and the negative pole of the load. Voltage range: The power supply voltage range of the 5-wire meter head is 4~28V, that is, the voltage connected to the thin red wire cannot exceed 28V. About the concept of load and power supply When discharging: batteries, switching power supplies, and transformers are power sources, and resistors, lights, motors, and electrical equipment are loads. When charging: chargers, generators, and solar energy are power sources, and rechargeable batteries and accumulators are loads. |