    Item specifics
    • Brand Name Stlxy
    • Model Number ZK-4KX
    • Phase Single Phase
    • Current Type DC
    • Usage SVC
    • is_customized Yes
    Product Description


    Conversion efficiency: about 88%
     
    Soft start: yes (with high power and load module may fail when starting)
    Protection mechanism:
    Input anti-reverse connection;
    Output anti-reverse irrigation;
    Input undervoltage protection (4.8-30v adjustable, default 4.8v)
    Output overvoltage protection (0.5-31v adjustable, default 31V)
    Output overcurrent protection 0-4.1a (adjustable, default 4.1a)
    Overpower protection (0-50w adjustable, default 50W)
    Overtemperature protection (80-110 adjustable, default 110℃)
    Timeout protection (0-100h adjustable, off by default)
    Super capacity protection (0-60ah adjustable, off by default)
    Operating frequency: 180KHZ
     
    Dimensions: length * width * height 79mm*43mm*26mm
    Weight: 92g (including package)


     

     Method of use
    5.1. Switch display parameters -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.
    5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
    5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
    5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate encoder to switch two states.After setting, long press U/I to return to the normal interface.
    5.5. Setting of protection parameters on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate encoder to select which bit you want to set the protection parameter.Long press the rotary encoder to set the protection parameters on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection parameters are turned on by default.).Rotate the encoder left and right to make the parameters bigger and smaller.After setting, long press U/I to return to the normal interface.
    5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the encoder left and right to adjust the size of parameters.After the adjustment is completed, long press the rotary encoder to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. 
    Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.

    Cautions
    7.1. Short connection between input IN and output OUT of the module is forbidden, or the constant current function will fail.
    7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
    7.3. If the module wants to output with full load, the input voltage should be above 8V. When the input voltage is 5V, the output power is about 15W.The maximum module current value is 4A, subject to the maximum output power, such as 17V, the current should not be greater than 2A.
    7.4. When this module is used over 3A and 35W, please strengthen heat dissipation!!!
    7.5. The module has input undervoltage protection function, which is about 4.8v by default (it can be set), and the output will be automatically disconnected after the value is lower than this value (note that the voltage at the module port is lower than the undervoltage protection threshold, and when the input current is relatively large, do not ignore the partial voltage on the input wire).
    123112313未标题-1

    Recomendación destacada

    Imágenes del cliente

    login <form action="" method="POST" name="customer_upload" enctype="multipart/form-data"> <table width="100%" border="0" cellspacing="0" cellpadding="0" class="tableStyle_1"> <input type="hidden" name="cmod" value="customer_upload_images" /> <tr> <td colspan="3"> <h2 class="margin_t pad_1em">Cargar foto en officematics.com</h2> </td> </tr> <tr> <td class="b g_t_r pad_r_5px">Images URL</td> <td class="g_t_l" colspan="2"><input type="file" name="images_file" class="name_win" ></td> </tr> <tr> <td>&nbsp;</td> <td colspan="2"><button type="submit"><span>Enviar</span></button></td> </tr> </table> </form>

    Vídeos de los clientes

    login <form action="" method="POST" name="customer_upload" enctype="multipart/form-data"> <table width="100%" border="0" cellspacing="0" cellpadding="0" class="tableStyle_1"> <input type="hidden" name="cmod" value="customer_upload_videos" /> <tr> <td colspan="3"> <h2 class="margin_t pad_1em">Cargar vídeos en officematics.com</h2> </td> </tr> <tr> <td class="b g_t_r pad_r_5px">Nombre de vídeos</td> <td class="g_t_l" colspan="2"><input type="text" name="videos_name" class="inp name_win" ></td> </tr> <tr> <td class="b g_t_r pad_r_5px">URL de YouTube</td> <td class="g_t_l" colspan="2"><input type="text" name="videos_url" class="inp name_win" ></td> </tr> <tr> <td>&nbsp;</td> <td colspan="2"><button type="submit"><span>Enviar</span></button></td> </tr> </table> </form>

    Etiquetas de productos:

    A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9

    Comparar productos y votar ahora!

    Especiales | Productos nuevos | Reseñas de productos

    Categorías calientes

    Accesorios de ordenador portátil ,

    Newsletter