- 0Carrito
-
Su carrito está vacío.
-
más artículos en el carro...
Carro Total: $0.00
Pasar por caja
Su carrito está vacío.
Carro Total: $0.00
Pasar por caja
|
Item specifics
Product Description
![]() ![]()
Type1 Descripition: Microcomputer time controllerTiming range: 00:00~99:59 0000~9999 SPower : AC110V~220V /10A/2200W (Max);DC12V/20A /240W (Max) DC24V/20A/480W (Max)Product size: 67×45×34mmHole size: 63×42mmProduct weight:63g(110~220V)Package content:1Pcs * AC 110-220V/DC12V/DC24V Time Controller![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() Type2 Descripition: Specifications: Model: Time Delay RelayTiming range: 0-999s,0-999m,0-999hPower supply voltage: AC 110V-220VLED Display: Red + Blue Dual DisplaySize: 79 x 26 x 43mmHole size: 72 x 40mmInstruction Manual: Before use, first remind the user to pay attention. After setting the data, you must wait for 6s. After 6s, the module will automatically save the memory setting data. ...Short press the SET button once to enter the time setting mode. The red digital tube flashes, adjust the timing time T1 by pressing the button plus or the button minus. After T1 is set, press the SET button again, and the green digital tube flashes. Set the timing by pressing the button plus or minus. After the time T2 and T2 are set, short press the SET button again, the system will automatically save the memory setting time or wait for 6s, the module will automatically save the data after 6s.Long press SET to enter the parameter setting mode. There are two sets of parameters for users to choose P0 and P1. In the current mode, short press SET to switch between P0 and P1. Under the P0 parameter, you can set the timing mode that suits you by pressing the button plus or minus. Under the P1 parameter, the working mode can be set by adding or subtracting buttons.P0--0: T1 timing time mode is secondsP0--1: T1 timing time mode is minuteP0--2: T1 timing time mode is whenP1--0: The relay is closed after delaying T1 time (T1 timing)P1--1: The relay is released after delaying T1 time (T1 timing)P1--2: After a delay of T1, the relay is closed (T1 timing), and after a delay of T2, the relay is released (T2 timing), and it ends.P1--3: After a delay of T1, the relay is released (T1 timing), and after a delay of T2, the relay is closed (T2 timing), and it ends.P1--4: The relay is closed after a delay of T1 time (T1 timing), and after a delay of T2, the relay is released (T2 timing), and the cycle repeats.P1--5: The relay is released after a delay of T1 time (T1 timing), and then after a delay of T2, the relay is closed (T2 timing), and the cycle repeats.Example: For example, a customer needs to turn on for 10 seconds and turn off for 20 seconds, and the cycle continues. The setting method is as follows:T1 setting time 10, T2 setting time 20P0-0 (T1 timing range is seconds)P1-5 (The timer working mode is to work first and then stop and keep looping)Wiring Method:![]()
Calificación media:5 ( 0 Comentarios )
Escribir un comentario
Recomendación destacada
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||