1 Working voltage: DC 12V (6-24V)
2 Working current: 10-16MA 3 MODBUS RTU 03 06 16 command control mode 4 Three functional modes can be selected by jumpers: 8 channel input/8 channel output/4 input 4 output 5 Input mode: support 3.3V/5V TTL level input, there are two input modes: low level input (default) and high level input 6 In output mode: 5V TTL level, low level (default)/high level output 7 In MODBUS command mode, it can support up to 247 devices to be used in parallel 8 Input port status supports query (default) and automatic reporting 9 The default baud rate is 9600BPS, which can be configured to support 1200 2400 4800 19200 baud rate 10 Size: 44*31*15 11 Weight: 9 grams (no Pin), 10 grams (with Pin), 12.5 grams (with Terminals) Instruction manual Please ask us after the purchase Application Automated industry PLC Digital in to RS485/RS485 to Digital out Smart Home,Home Automation ; Identification system; CCTV Camera PTZ Control; Security system; LED dot matrix screen; RS485 remote control;
Choose different functions through jumpers on the board:As 8-channel inputs Please refer to ''N4DIG08 MODBUS RTU instruction (8-channel input)'' As 8-channel outputs Please refer to ''N4DIG08 MODBUS RTU instruction (8-channel output)'' As 4 input 4output Please refer to ''N4DIG08 MODBUS RTU instruction (4 Input 4 Output)'' As an 8-channel input wiring diagram:
As an 8-channel output wiring diagram:
As a 4 input 4 output wiring diagram:
RS485 Wiring diagram:
|