Item specifics
Product Description
Product Highlights 1. Support Lead-acid battery and Acting Battery, voltage range:6V~60V; 2. Can display voltage,percent of battery,charging time at the same time through LCD; 3. The function is very powerful,realizes the automatic charge control, the control charge time, also may set up and uploads the corresponding parameter through the serial port. Product Parameter ·Product Name: NC charging module; ·Product model: XY-L10A; ·Control voltage: DC6-60V; ·Control current: ≤10A; ·Control accuracy: 0.1V; ·Type of output: Direct output; ·Voltage error: ±0.1V; ·Scope of application: Various battery lithium batteries; ·Size:79*42mm. Function description1. Automatic Charge control function:By setting the volt-HI:'UP' volt-LI:'dn';When the battery voltage is below the volt-LI:'dn',the relay leads,the charger begins to charge the battery;when the battery voltage is up to volt-HI:'UP',the relay is diconnected and the automatic charge is completed once; 2. Charge Time Control Function: How to turn on the time control function? After entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is:--:--h, the default does not turn on time control function; After the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI'dn', the charger began to charge the battery, the system began to clock; During the timing, the battery voltage ≥ volt-HI'UP', relay disconnect; If the OP time is up, the battery voltage is still the lower volt-LI'dn', the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Press any key to stop flashing; Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours. 3. Serial data upload and parameter setting function: The system supports UART data upload and parameter setting UART:115200,8,1
Data Upload message Format: Battery voltage + battery percent + charge time + charge status 12.0V,020%,00:10,OP
Parameter Setting a) Press and hold the SET key to enter the setting interface; b) Switch the parameters you want to set by short press SET; c) After the selection of parameters, it can be set by the UP/DOWN key to support the short press, long press (fast increase or decrease), To set other parameters, repeat step b, c); After all parameters are set, long press set key to exit and save
|