- 0Cart
-
Your shopping cart is empty.
-
more items in the cart...
Cart Total: $0.00
Proceed to Checkout
Your shopping cart is empty.
Cart Total: $0.00
Proceed to Checkout
|
Item specifics
Product Description
10A 12V Time Relay Adjustable Time Delay Relay Module LED Digital Timming Relay Timer Delay Trigger Switch for Motor LEDModel: YYC-2S 24 Common functions, to meet more application needs; can control solenoid valves, pumps, motors, lights, etc. Input Voltage: DC 12V Output power: 10A Relay Time range: 0.01s-999m Adjustable Description of the wiring port: DC+: input DC power supply positive DC-: input DC power supply negative IN+: positive input terminal IN-: signal input terminal NO: relay normally open interface, the relay is suspended before the suction, after the suction and short circuit with COM COM: relay common interface NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed. Function: P-11: Jog P-12: Self-locking P-13: Give signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay. P-14: Give signal, relay will stop automatically for A seconds; trigger re-time during delay P-15: Give signal, relay is automatically stopped for A seconds; trigger timing is triggered during delay P-16: Give signal, relay will stop automatically for A seconds; trigger reset during delay P-17: Give signal, relay is closed, input signal is disconnected, output is off after A seconds P-18: After power-on, the relay will immediately pull in, after a delay of A seconds, the power will be turned off; P-21: Disconnect the signal relay, after a delay of A seconds, the relay pulls in P-22: Give signal, after more than A seconds, the relay pulls in, the signal disappears, the relay stops. P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops. P-24: There is a signal. After more than A seconds, the relay is closed. When the signal disappears for more than A seconds, the relay stops. P-25: There is a signal after more than A seconds, the relay is closed, and after a signal exceeds A seconds, the relay stops. P-26: There is a signal. The relay stops after A seconds of suction, and the signal disappears. The relay stops again after A seconds. P-27: The pulse signal is detected and the relay is closed; if there is no pulse signal, the relay delays for A seconds; P-28: After power-on, after a delay of A seconds, the relay pulls in until the power is turned off. P-31: After power-on, the relay pulls in for A seconds, disconnects B seconds, infinite loop; power-off stops P-32: signal, start P-31 P-33: Give a signal, start P-31 infinite loop; give another signal to terminate the loop P-34: After power-on, after a delay of A seconds, the relay pulls in and closes after B seconds. P-35: There is a signal. After a delay of A seconds, the relay pulls in and closes after B seconds. P-36: There is a signal. After more than A seconds, the relay pulls in and closes after B seconds. P-37: There is a signal, the relay will stop automatically for A seconds, and then stop for 24 seconds. The signal trigger is invalid during A+B time. P-38: There is a signal, the relay will stop automatically for A seconds, stop and re-time for B seconds, and then automatically close for A seconds. P-41: There is no signal; the signal disappears; the relay works after the delay of A time. P-42: The signal disappears, after a delay of A time, the relay works; the end of work B time P-43: The signal disappears. After the A time, the relay works; the working B time ends. P-44: After power-on, the relay works for A time, and stops B time; the cycle stops automatically for C times. P-45: The power is not activated, after the signal is given; the relay works for A time, the B time is stopped; the cycle C stops automatically; the signal is given again, once again P-46: After the signal is sent for more than A times, the relay is closed; the suction is kept; the power is stopped. P-47: After the signal is sent for more than A times, the relay is closed for B seconds. P-48: In C seconds, after the signal is continuously sent for more than A times, the relay is closed for B seconds. Instructions: The power-on display “————” means to enter the standby state; Press K1 for the first time (more than 1 second is required to prevent false triggering) Screen display: P -11: K2 adjusts the main mode, K3 and K4 adjustment functions Press the second time K1, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit) Pressing the third K1, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Pressing the fourth K1, “————” means entering the standby state; Press K4 in standby mode to permanently turn off/on the display and switch the low power mode. X.XX decimal point in hundred, timing range: 0.01 seconds to 9.99 seconds XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds XXX has no decimal point, timing range: 1 second ~ 999 seconds XXX. The decimal point is in one place, the time range is from 1 minute to 999 minutes. Package Included: 1 x Time Delay Relay
Average rating:5 ( 0 reviews )
Write a review
Featured recommendations
|